Views: 0 Author: Rebecca | Senior FF&E Procurement Specialist Publish Time: 2026-11-16 Origin: Site
Specify a nurse station around the shift. That means a split-level worktop for standing and seated tasks, storage placed by how often items are used, and surfaces and joints that can be wiped in one pass. Most problems that show up after opening are visible on the shop drawing, which is why this guide follows the order in which they appear: worktop height, storage, the wipe path, surfaces, and the drawings to lock before fabrication.
A nurse station is often specified from an office furniture catalogue because it looks like a desk with lockers behind it. But staff use it differently: they stand up mid-sentence, hand over files, check medication labels, and wipe the worktop between patients. The numbers below are design starting points to test with your own staff, not universal standards.

Specify the station by posture and task. Standing handover, medication checks and seated charting need different worktop heights.
Place storage by how often items are used. Anything reached repeatedly should be within the standing zone, so the counter does not become the store.
Protect the wipe path: keep cables off the surface, leave one clear landing zone, and use sealed edges and upstands.
Check accessibility with your consultant. The ADA treats employee work areas and public-facing counters differently.
Lock the elevation, edge and upstand detail, storage schedule and equipment interfaces before production, and review a full-size mock-up where the station type repeats.
Many failures are geometric and are fixed at the drawing stage. Typical examples are:
a worktop at office height that makes tall staff stoop over a keyboard
a return end with no room for a trolley to pass without hitting the panel
a solid plinth that nobody can mop under
sockets, data points or equipment brackets added on site that cut through finished panels
Responsibility is often split. The furniture supplier draws the counter, the electrical consultant locates sockets and network points, and another party supplies equipment such as a medication cabinet. If these arrive on separate drawings, the counter is built to the furniture drawing and then modified on site.
The station is also judged twice. Staff notice reach, sightlines and where the printer sits within a week. The infection prevention team notices joints, the gap under the counter and whether surfaces and chairs can be wiped. A good specification answers both.

Clinical work at a station alternates between standing and sitting, so a single height suits neither well. A common solution is a split-level counter with a standing section on the public side and a seated section behind it.
Zone | Starting-point height | Starting-point depth | What to test |
Standing handover and filing | about 39.5–41 in (1000–1050 mm) | 18–20 in (450–500 mm) | Forearms rest without a shoulder lift, and papers are easy to read |
Medication preparation | about 35.5–37.5 in (900–950 mm) | about 24 in (600 mm) | Labels are in the near field and the prep tray sits inside the elbow line |
Seated charting | about 28.5–29.5 in (720–750 mm) | 25.5–27.5 in (650–700 mm) | The screen is at a comfortable eye level with the chair set correctly |
Accessible section | within 28–34 in (710–865 mm) | per consultant | Knee and toe clearance provided where required |
Printer and consumables ledge | about 33.5 in (850 mm) | about 20 in (500 mm) | Reachable without stretching and above trolley height |
Treat the rows other than the accessible section as starting points to test on a mock-up. A station staffed mainly by very tall and very short staff needs both extremes checked, not the average.
The ADA requires the tops of accessible work surfaces to be between 28 in (710 mm) and 34 in (865 mm) above the floor, with knee and toe clearance provided. Employee work areas have more limited requirements: they must be designed so that people with disabilities can approach, enter and exit them. Whether a given section of a station counts as an employee work area depends on the project. If the station has a counter facing patients or visitors, other provisions may apply. Ask your accessibility consultant to confirm which sections need what, and follow local codes if the project is outside the US.[ada]
Keep a seated charting position free of drawer banks and support panels where the knees go, so a wheeled chair can enter. Put drawers under the standing section and in the returns. Be careful with depth, because a very deep charting surface pushes the screen away and collects objects at the back.
Instead of counting linear metres, start from the shift. Ask what staff reach for repeatedly, what they need once a day, and what must be locked. Position matters more than volume, because a cabinet that is out of reach tends to stay empty while supplies pile up on the counter.
Storage group | Typical contents | Placement rule | Risk if misplaced |
Immediate reach | gloves, wipes, labels, forms, scanner | between hip and shoulder height at the standing section | The counter becomes a store |
Shift reserve | paper, spare forms, dressing packs | returns or an end unit | Staff leave the station to fetch supplies |
Locked | controlled stock, records, keys | within the sightline of the seated position | Cabinets left open, audit exceptions |
Personal | bags, coats, water bottles | away from the worktop | Bags end up on the counter |
Equipment parking | trolleys, scales, wheelchairs | a dedicated bay | Repeated impact on end panels |
Medication-related storage should follow the pharmacy's and the hospital's own access-control and audit requirements. A separate cabinet is often easier to manage than a locker bank. Personal storage is easy to forget in a healthcare specification, but a station with nowhere to put a bag will end up with bags on the worktop.
The wipe path is the route a cloth can take across the worktop without being lifted. Monitor bases, keyboards, stacks of forms and loose cables interrupt it. Three specification choices protect the path:
A continuous surface: Use a worktop with a sealed upstand, so a wipe runs from the front edge to the wall without meeting a loose joint.
A cable strategy: Route cables below the surface or in a back channel, and place grommets against the equipment schedule.
A landing zone: Leave one area of the counter deliberately clear, defined by the geometry rather than a label, where trays, bags and samples can be set down.

Dispenser placement belongs to your infection prevention team. It can also be subject to fire and building code limits, so confirm both locally. Whatever the position, avoid placing dispensers where drips fall on stored supplies.
Cleaning access is often lost to appearance. A plinth that runs to the floor looks tidy but cannot be mopped under. A toe recess of adequate height, with the floor finish continuing under the unit, lets a mop head pass. Whether this is needed depends on the cleaning method in use, so confirm it with the facilities team.
Start with the products your cleaning team actually uses. Ask the infection prevention team for the current agent list, then request each supplier's chemical resistance data for the proposed surface and edge. Specify by layer:
Working surface: a non-porous face with a sealed edge and a defined upstand joint
Vertical faces: a finish that stays acceptable under the same wipe regime, approved from a physical sample
Substrate: every cut edge sealed
Hardware: simple and accessible for cleaning. Check that hinges, runners and any damping mechanisms are compatible with your cleaning products, and ask about the warranty terms for cleaning
Keep a dated sample of each approved surface at the project. It helps settle disputes later about whether a mark is a defect or residue. For a deeper checklist on edges, joints and disinfectant compatibility, use the same approach as for exam room casework, instead of repeating it station by station.
After release, each change means a cut panel, a revised delivery or a site visit. Before the drawing set leaves the office, lock these four items:
Elevation: every socket, data point and call button located against the counter geometry.
Section: the edge profile, upstand height, substrate and seal, and the drip path at any dispenser or sink.
Storage schedule: each compartment with its lock type and contents.
Interface list: who supplies and who installs the equipment that sits on or in the counter, and who cuts and seals the openings for cables.
Where the same station type repeats on several floors, build one full station and review it before the run starts. Have the clinical team stand at it and test:
reach to the printer and scanner
the sightline from the seated position to the corridor
whether a cloth can travel the whole worktop without lifting
whether a trolley passes the end panel without contact
Record the changes in a signed punch list. It is cheaper to correct a mock-up than a finished run.
Nurses Station Counter Hospital Corner Reception Desk
What height should a nurse station worktop be?
A split-level counter usually works better than one height. Use a standing section for handover and medication checks and a lower seated section for screen work. Treat the ranges in this guide as starting points and test them with your staff. Accessible work surfaces must fall within 28–34 in (710–865 mm) under the ADA.
Does the ADA require a nurse station to be accessible?
It depends on the area. Employee work areas must allow approach, entry and exit. Public-facing counters may have additional requirements, so confirm with your accessibility consultant and local code.
Can office furniture be used for a nurse station?
Only for the parts that are genuinely office work, such as a seated charting position. Check sealed edges, cleaning access and hardware compatibility before using any office product in a clinical area.
How much storage does a nurse station need?
Start from the shift, not from a volume figure. Plan immediate-reach items, a shift reserve, locked storage, personal storage and a trolley bay, then size each from the actual workflow.
How do you keep cables off the worktop?
Draw them on the elevation. Specify a back channel or under-counter route, grommets placed against the equipment schedule, and a path down inside the return.
Which surface suits a station that is disinfected daily?
It depends on the clinic's products. Request chemical resistance data against your agent list, check the edge and upstand detail, approve a physical sample and retain it at the project.
When should the mock-up be reviewed?
Before the production run starts, with the clinical team standing at the counter.
Hongye Healthcare Furniture can review your station elevations, storage schedule and equipment interfaces before production. See our hospital furniture solutions for nurse station and other ward furniture, and our hospital seating range for nurse station seating. To get started, send your floor plan, staffing pattern and cleaning product list.